Power Supply
|
Component |
Specifications |
|---|---|
|
Transformer Input |
The plug-in transformer shall plug into a 120 VAC 60 Hz outlet not controlled by a switch and all 16- to 18-gauge wire shall run through conduit and connect to the ES501 or ES502 Transformer Enclosure.
|
|
Standby Battery |
|
|
Auxiliary |
|
|
Bell Output |
12 VDC at 2 A Max |
|
All circuits are inherent power limited except the red battery wire and AC terminal. See 50 VA-100 VA Transformer Selections for more information. |
|
Communication Features
-
Built-in network communication to DMP Model SCS-1R or SCS-VR Receivers
-
Built-in 128- or 256-bit or TLS-encrypted communication to DMP SCS-1R or SCS-VR receivers. TLS encryption is supported with SCS-VR receivers only.
-
Optional 263LTE Series Cellular Module
-
Can operate as a local panel
Note: 256-bit encrypted messages sent to SCS-1R receivers require an SCS-104 Receiver Line Card with firmware version 102 or higher.
TLS-encrypted messages sent to SCS-VR receivers require firmware version X or higher.
Panel Zones
Ten burglary zones (zones 1–10) with 1 kΩ–10 kΩ EOL resistance, automatically detected
Keypad Bus
Connect up to 16 of the following supervised keypads and expansion modules to the two keypad bus connections:
-
Alphanumeric keypads
-
Graphic Touchscreen keypad
-
4, 8, and/or single-zone expansion modules
-
Access control modules
LX5-LX9 Bus
You can connect the following devices to the LX-Bus connections provided on the panel:
-
4, 8, 16 and/or single-zone expansion modules
-
Single-zone detectors
-
Relay output expansion modules
Outputs
The XR650 provides 2 SPDT relay outputs that require the installation of 2 Model 305 relays, each rated 1 A at 30 VDC resistive (power limited sources only). A Model 431 Output Harness is required to use these outputs.
The XR650 also provides 4 open-collector outputs rated for 50 mA each. The open-collector outputs provide ground connection for a positive voltage source. A Model 300 Output Harness is required to use these outputs.
Enclosures
The XR650 is shipped in an enclosure with end-of-line resistors, battery leads, and a user reference card that includes a QR code to the online user guide. Transformers are ordered separately.
Refer to the table below for enclosure model information:
|
Enclosure Model |
Size |
Color |
Construction
|
|---|---|---|---|
|
350 |
17.5”W x 13.5”H x 3.5”D |
Gray (G) or Red (R) |
18-gauge |
|
350A |
17.5”W x 13.5”H x 3.75”D |
Gray (G) |
18-gauge with 16-gauge door |
|
341 |
13.22”W x 7.0”H x 3.5”D |
Gray (G) |
20-gauge |
|
349 |
12.5”W x 11.5”H x 3.5”D |
Gray (G) |
20-gauge |
|
352X |
14.5”W x 32.0”H x 4.0”D |
Gray (G) |
16-gauge |