XR650 Installation and Programming Guide

Communication

This menu allows you to configure communication options for the panel. The information you program varies depending on the type of communication selected.

Program the Panel at the Keypad

  1. Press 6653 (PROG), then CMD at the keypad to enter the PROGRAMMER menu.

  2. Press CMD until you see COMMUNICATION, then press any select key or area.

  3. Configure the following options as needed:

Keypad Display

Description

Account Number

ACCOUNT NUMBER

Enter the account number (1–65535) that the receiver uses to identify the panel. Do not enter leading zeros for account numbers with 4 or fewer digits. The default is 12345.

Transmit Delay

XMIT DELAY

Enter the number of seconds (15-45) the panel waits before sending burglary zone reports to the receiver. Enter 0 to disable the transmit delay. The default is 30 seconds.

See Transmit Delay.

Communication Path

PATH: -

Enter the communication path you are programming. You can configure up to 8 communication paths. Path 1 is always primary but other paths may be programmed as additional primary or backup paths.

See Communication Paths.

Communication Type

COMM TYPE: NONE

NONE NET CEL

Select one of the communication types for this path:

  • NONE (default) — Disable communication on this path and end communication programming. Use for local systems.

  • NET — Use the panel’s onboard network connection.

  • CEL — Use the cellular network

See Communication Types.

Path Type

PATH TYPE: BACKUP
PRIMARY BACKUP

📍 Displays if Path is 2-8.

Select the path type. The default is BACKUP.

If the primary communication type is Cellular, the backup communication type can only be Network.

See Communication Paths.

Test Frequency

TEST FREQ: 1 DY

Enter a number (1-60), then select DY (Day) or HR (Hour) using the far-right Select key or area to set the test report frequency. The default is 1 DY (Day).

Test Time

TEST TIME
0:00 AM

Enter the hour, minute and AM/PM to set the time when test reports are sent.

Enter 0:00 AM to disable this feature. The default is 0:00 AM.

Check-in

CHECKIN
NO YES ADP ADP3

📍 Displays if Communication Type is Network, or Cellular.

  • YES (default for Network and Cellular) — Enable Check-in reports to supervise the panel for communication with the receiver.

  • NO — Disable Check-in reports.

  • ADP — Use the Check-in programming from the primary path for the backup path if the primary path becomes unavailable.

  • ADP3 — Use a 3-minute Check-in and Fail Minutes for the backup path if the primary path becomes unavailable. This option also sends a Communication Trouble (S10) message if the cell tower is unavailable for 3 minutes.

Check-in Minutes

CHECKIN MINS: 100

📍 Displays if Check-in is set to Yes.

Enter the number of minutes between Check-in reports while the panel is armed or disarmed.

The valid range is 2-100 minutes for Network or 1-400 for Cellular. The default is 100.

Fail Minutes

FAIL MINS: 240

📍 Displays if Check-in is set to Yes.

Enter the number of minutes (2-240) the receiver waits before reporting the panel as not responding after Check-in reports are missed. Configure Fail Mins to be equal to or greater than Check-in Mins.

The default is the value of Check-in Mins for Cellular and 240 minutes for Network.

Use Receiver Host Name

USE RCVR HOST NAME
NO YES

📍 Displays if Communication Type is Network.

NO (default) — Set an IP or IPv6 address.

YES — Use a host name.

See Receiver Configuration.

Receiver Host Name

RCVR HOST NAME
-

📍 Displays if Communication Type is Network and Use Receiver Host Name is set to Yes.

Enter a host name. Host names can be up to 63 characters and include the following:

  • a-z

  • A-Z

  • 0-9

  • hyphen (-)

  • period (.)

Ensure the host name is unique and cannot be duplicated on the network. If you enter a host name, you do not need to enter an IP address.

Use IPV6 Address

USE IPV6
NO YES

📍 Displays if Communication Type is Network and Use Receiver Host Name is set to No.

NO (default) — Use an IPv4 address.

YES — Use an IPv6 address.

See Receiver Configuration.

Receiver IPv6 Address

RECEIVER IPV6
-

📍 Displays if Communication Type is Network, Use IPv6 Address is set to Yes, and Use Receiver Host Name is set to No,

Enter the IPv6 address where the panel sends network messages.

Ensure the address is unique and cannot be duplicated on the network. Enter all 32 digits and leave out the semicolons.

Receiver IP Address

RECEIVER IP
000.000.000

📍 Displays if Communication Type is Network, Use IPv6 Address is set to Yes, and Use Receiver Host Name is set to No.

Enter the receiver IP address where the panel sends network messages.

Ensure the address is unique and cannot be duplicated on the network. Enter all 12 digits and leave out the periods.

Receiver Port

RECEIVER PORT
2001

Enter the receiver port number (1-65535). The default is 2001.

Advanced Communication Programming

ADVANCED? NO YES

NO — Return to Communication Path to configure another path.

YES — Enter the Advanced Programming for the current communication path.

Cell APN

CELL APN
SECURECOM400

📍 Displays if Communication Type is Cellular.

Enter the first APN (Access Point Name).

The APN can contain two lines of 16 characters that equal up to 32 characters. The default is SECURECOM400.

Fail Test Frequency

FAIL TEST HRS: 0

📍 Displays if Communication Path is Backup.

Enter the number of hours (0—24) between Fail Test reports. This option applies to Backup and Adaptive communication paths when the previous path in the path group fails.

Enter 0 to send test reports according to the Test Reports programming. The default is 0.

Protocol

PROTOCOL: TCP

📍 Displays if Communication Type is Network.

TCP (default) — Communicate over the network using TCP protocol.

UDP — Communicate over the network using UDP protocol.

Retry Seconds

RETRY SECONDS: 6

📍 Displays if Communication Type is Network.

Enter the number of seconds (6-15) the panel waits before retrying communication if the receiver does not acknowledge a message. The default is 6 seconds.

The panel retries for up to 1 minute before sending a Network Trouble message.

Duplicate Alarms

DUPLICATE ALARMS
NO YES

📍 Displays if Communication Path is Backup.

NO (default) — Do not duplicate alarms.

YES — Duplicate all alarms from the group’s primary path.

Alarm Reports

ALARM YES

NO YES SPV

📍 Displays if Communication Path is Primary.

  • YES (default) — Send the following reports for all zone types:

    • Alarm

    • Bypass

    • Reset Restore

  • NO — Do not send alarm reports.

  • SPV — Send the following reports for Supervisory zones only:

    • Alarm

    • Bypass

    • Reset

    • Restore

Supervisory/Trouble Reports

SPV/TRBL YES

NO YES SPV

📍 Displays if Communication Path is Primary.

  • YES (default) — Send the following reports for all zone types:

    • Trouble

    • Low Battery

    • Missing

    • Fault

    • Restorals

    • System Troubles

    • System Restoral

  • NO — Do not send Supervisory/Trouble reports.

  • SPV — Send the following reports for Supervisory zones only:

    • Trouble

    • Low Battery

    • Missing

    • Fault

    • Restorals

    • System Troubles

    • System Restoral

Opening/Closing and User Reports

O/C USER NO YES

📍 Displays if Communication Path is Primary.

YES (default) — Send the following user reports:

    • Opening

    • User code changes

    • Closing

    • Schedule changes

    • Bypass

    • Holiday date changes

    • Reset

NO — Do not send Opening/Closing User reports.

Door Access Reports

DOOR ACS DENY

NO YES DENY

📍 Displays if Communication Path is Primary.

  • DENY (default) — Send Door Access Denied reports only.

  • NO — Do not send Door Access reports.

  • YES — Send Door Access Granted and Door Access Denied reports to the receiver.

Note: Door Access Granted reports are only sent if the keypad is selected in
System Reports > Access Keypads.

Panic Test Reports

PANIC TST NO YES

📍 Displays if Communication Path is Primary.

NO (default) — Do not send Panic Test reports.

YES — Send Panic Zone Test Verification and Panic Zone Test Failure reports to the receiver.

Note: Panic Zone Test Verification and Panic Zone Failure messages are the same as those generated during the Walk Test.

See Perform a Walk Test.

Send Communication Trouble

SEND COMM TRBL
NO YES

NO (default) — Do not send Communication Trouble messages.

YES — Sends Communication Trouble messages, including the Communication Path and Communication Type that experienced the failure.

  1. When you are finished, continue programming additional menus as needed, or press CMD until STOP displays, then press any select key or area to save the panel programming.

Program the Panel in Dealer Admin

Before You Begin

  • Verify the panel is connected to network

  • Log in to Dealer Admin.

  1. Go to Customers, then select the System Name.

  2. Go to Programming > Communication.

  3. Configure the following options as needed:

Basic Programming

Dealer Admin Field

Description

Account Number

The account number the receiver uses to identify the panel. The default is 12345.

Transmission Delay

Enter the number of seconds (15-45) the panel waits before sending burglary zone reports to the receiver. Enter 0 to disable the transmit delay. The default is 30 seconds.

See Transmit Delay.

Communication Path

Enter the communication path you are programming. You can configure up to 8 communication paths.

Path 1 is always primary. Select + Add Communication Path to program additional primary or backup paths.

See Communication Paths.

Communication Type

Select one of the communication types for this path:

Network — Use the panel’s onboard network connection.

Cell — Use the cellular network.

See Communication Types.

Path Type

📍 Displays if Path is 2-8.

Select the path type. The default is Backup.

If the primary communication type is Cellular, the backup communication type can only be Network.

See Communication Paths.

Test Report

Yes (default) — Send test reports.

No — Do not send test reports.

Test Frequency Number

Enter the number (1-60) of days or hours (determined by Test Frequency Unit) between sending test reports. The default is 1.

Test Frequency Unit

Select Days or Hours as the unit of measurement for the Test Frequency Number. The default is Days.

Test Time

Enter the time when test reports are sent.

Leave the field blank disable this feature. The default is blank.

Check-in

📍 Displays if Communication Type is Network or Cell.

  • Yes (default for Network and Cellular) — Enable Check-in reports to supervise the panel for communication with the receiver.

  • No — Disable Check-in reports.

  • Adaptive — Use the Check-in programming from the primary path for the backup path if the primary path becomes unavailable.

  • Adaptive 3 — Use a 3-minute Check-in and Fail Minutes for the backup path if the primary path becomes unavailable. This option also sends a Communication Trouble (S10) message if the cell tower is unavailable for 3 minutes.

Check-in Minutes

📍 Displays if Check-in is set to Yes.

Enter the number of minutes between Check-in reports while the panel is armed or disarmed.

The valid range is 2-100 minutes for Network or 1-400 for Cellular. The default is 100.

Fail Time

📍 Displays if Check-in is set to Yes.

Enter the number of minutes (2-240) the receiver waits before reporting the panel as not responding after Check-in reports are missed. Configure Fail Mins to be equal to or greater than Check-in Mins.

The default is the value of Check-in Mins for Cellular and 240 minutes for Network.

Use Receiver Host Name

📍 Displays if Communication Type is Network.

Toggle ON to use a host name.

Toggle OFF to set an IP or IPv6 address.

See Receiver Configuration.

Receiver Host Name

📍 Displays if Communication Type is Network and Use Receiver Host Name is set to Yes.

Enter a host name. Host names can be up to 63 characters and include the following:

  • a-z

  • A-Z

  • 0-9

  • hyphen (-)

  • period (.)

Ensure the host name is unique and cannot be duplicated on the network. If you enter a host name, you do not need to enter an IP address.

Use IPv6

📍 Displays if Communication Type is Network and Use Receiver Host Name is set to No.

Toggle ON to use an IPv6 address.

Toggle OFF to use an IPv4 address.

See Receiver Configuration.

Receiver IPv6 Address

📍 Displays if Communication Type is Network, Use IPv6 Address is set to Yes, and Use Receiver Host Name is set to No.

Enter the IPv6 address where the panel sends network messages.

Ensure the address is unique and cannot be duplicated on the network. Enter all 32 digits and leave out the semicolons.

Receiver IP Address

📍 Displays if Communication Type is Network, Use IPv6 Address is set to Yes, and Use Receiver Host Name is set to No.

Enter the receiver IP address where the panel sends network messages.

Ensure the address is unique and cannot be duplicated on the network. Enter all 12 digits and leave out the periods.

Receiver IP Port

Enter the receiver port number (1-65535). The default is 2001.

Advanced Programming

Select the Advanced drop-down arrow to program the following advanced communication options:

Dealer Admin Field

Description

Fail Test Hours

📍 Displays if Communication Path is Backup.

Enter the number of hours (0-24) between Fail Test reports. This option applies to Backup and Adaptive communication paths when the previous path in the path group fails.

Enter 0 to send test reports according to the Test Reports programming. The default is 0.

Cell APN

📍 Displays if Communication Type is Cellular.

Enter the APN (Access Point Name).

The APN can contain two lines of 16 characters that equal up to 32 characters. The default is SECURECOM400.

Protocol

📍 Displays if Communication Type is Network.

TCP (default) — Communicate over the network using TCP protocol.

UDP — Communicate over the network using UDP protocol.

Retry Seconds

📍 Displays if Communication Type is Network.

Enter the number of seconds (6-15) the panel waits before retrying communication if the receiver does not acknowledge a message. The default is 6 seconds.

The panel retries for up to 1 minute before sending a Network Trouble message.

Duplicate Alarms

📍 Displays if Communication Path is Backup.

Toggle ON to duplicate all alarms from the group’s primary path.

Toggle OFF to disable this option.

Alarm Reports

📍 Displays if Communication Path is Primary.

  • Yes (default) — Send the following reports for all zone types:

    • Alarm

    • Bypass

    • Reset Restore

  • No — Do not send alarm reports.

  • SPV — Send the following reports for Supervisory zones only:

    • Alarm

    • Bypass

    • Reset

    • Restore

Supervisory/Trouble Reports

📍 Displays if Communication Path is Primary.

  • Yes (default) — Send the following reports for all zone types:

    • Trouble

    • Low Battery

    • Missing

    • Fault

    • Restorals

    • System Troubles

    • System Restoral

  • No — Do not send Supervisory/Trouble reports.

  • SPV — Send the following reports for Supervisory zones only:

    • Trouble

    • Low Battery

    • Missing

    • Fault

    • Restorals

    • System Troubles

    • System Restoral

Opening/Closing & User Reports

📍 Displays if Communication Path is Primary.

Toggle ON to send the following user reports:

  • Opening

  • User code changes

  • Closing

  • Schedule changes

  • Bypass

  • Holiday date changes

  • Reset

Toggle OFF to disable this option.

Door Access Reports

📍 Displays if Communication Path is Primary.

  • Deny (default) — Send Door Access Denied reports only.

  • Yes — Send Door Access Granted and Door Access Denied reports to the receiver.

  • No — Do not send Door Access reports.

Note: Door Access Granted reports are only sent if the keypad is selected in
System Reports > Access Keypads.

Panic Test

📍 Displays if Communication Path is Primary.

Toggle ON to send Panic Zone Test Verification and Panic Zone Test Failure reports to the receiver.

Toggle OFF to disable this option.

Note: Panic Zone Test Verification and Panic Zone Failure messages are the same as those generated during the Walk Test.

See Perform a Walk Test.

Send Communication Trouble

Toggle ON to send Communication Trouble messages, including the Communication Path and Communication Type that experienced the failure.

Toggle OFF to disable this option.

  1. When you are finished, select one of the following options:

    • If you are finished with all programming — Select Send All Changes at the top of the screen. This sends all programming changes to the panel.

    • If you are finished programming Communication only — Select the More icon menu.png , then select Send Communication. This only sends communication programming changes to the panel.

Reference

Transmit Delay

This option delays burglary alarm reports before they are sent to the monitoring center. This gives users time to disarm the system before an alarm is reported. Other zone types are sent immediately. Alarm bells and relay outputs are not delayed.

Abort Reports

If the system is disarmed before the transmit delay expires, the panel sends an Abort Report (S45) instead of an alarm report.

Alarm Cancelled Reports

If the system is disarmed after the alarm report is sent but before the Bell Cutoff time expires, the panel sends an Alarm Cancelled (S49) report.

Communication Paths

Each primary path creates a path group, which consists of the primary path and any subsequent backup paths. The panel normally communicates using the primary path and switches to a backup path only if the primary path fails or if a backup path is configured to duplicate messages.

Primary and Backup Paths

  • Path 1 is always configured as the primary communication path.

  • Paths 2-8 can be configured as either primary or backup paths.

  • Path 8 cannot be configured with a backup communication path.

  • The panel normally communicates using the primary path. Backup paths are used only if the primary path fails or when configured to duplicate messages.

Communication Types

This options determines the network used to communicate to the monitoring center. Depending on the installation, the panel can be connected over Ethernet or a cellular network.

Systems that do not report to a monitoring center can operate without an active communication method. Selecting None is typically used for local systems.

Receiver Configuration

This option determines how the panel communicates with the monitoring center.

Receiver Host Name

A receiver host name identifies the monitoring center receiver using a name instead of an IP address. Use a host name to allow the panel to continue communicating if the receiver's IP address changes without requiring the panel configuration to be updated. When a receiver host name is configured, a receiver IP address is not required.

IP Addressing

An IP address identifies the monitoring center receiver using a numeric network address. IPv4 is the most commonly used IP address format. IPv6 is a newer IP address format used on networks configured for IPv6.