This menu allows you to configure system-wide parameters.
Program the Panel at the Keypad
-
Press 6653 (PROG), then CMD at the keypad to enter the PROGRAMMER menu.
-
Press CMD until you see SYSTEM OPTIONS, then press any select key or area.
-
Configure the following options as needed:
|
Keypad Display |
Description |
|---|---|
Instant Arming
INST ARM NO YES |
NO (default) — INSTANT does not display on the arming keypad during arming. YES — INSTANT displays on the arming keypad for selecting during the exit countdown delay when arming fewer than all system areas. When INSTANT is selected, entry and exit delays for the areas being armed are ignored. Entry delays for previously armed areas are not affected. |
Closing Wait
CLS WAIT NO YES |
NO (default) — Disable this option. YES — The keypad displays ONE MOMENT… while waiting for an acknowledgement from the receiver before arming the selected areas and performing a Bell Test (if selected). Exit delays begin after the Closing Wait. |
Entry Delay 1, 2, 3, and 4
ENTRY DLY 1: 30 ENTRY DLY 2: 60 ENTRY DLY 3: 90 ENTRY DLY 4: 120 |
Enter the number of seconds (30-250) for the Entry Delay time for all Exit type zones. When an armed Exit zone is faulted, the keypad prewarn tone sounds. Keypads programmed to prewarn for that zone display ENTER CODE:- and the zone name causing the Entry Delay. Note: For UL installation's, the combined Transmit Delay (Abort Window) and Entry Delay cannot exceed 1 minute. |
Cross Zone Time
CRS ZONE TM: 4 |
Enter the number of seconds (4-240) allowed between zone faults. The default is 4. Enter 0 to disable this option. When zones are cross-zoned, ensure the same zone or a second cross-zoned zone faults within the programmed time for an Alarm report for both zones to send to the receiver. If the Cross Zone time expires without the second zone faulting, only a zone fault from the first zone is reported. See Cross Zoning. |
Zone Retard Delay
RETARD DLY: 10 |
Enter the retard delay time (1-250 seconds) for Fire, Supervisory, Auxiliary 1, Auxiliary 2, Arming, Holdup, and Panic type zones. The default is 10 seconds. Enter 0 to disable this option. This delay only applies when a zone is shorted. The zone needs to remain shorted for the entire delay period before the panel recognizes the fault. |
Power Fail Hours
POWER FAIL HRS: 1 |
Enter the number of hours (1-15) AC power can be off before an AC Power Failure report is sent to the receiver. The default is 1 hour. Enter 0 to disable this option. |
Swinger Bypass Trips
SWGRBYPS TRIPS: 2 |
Enter the number of times (1-6) a zone can enter an Alarm or Trouble condition within 1 hour before being automatically bypassed. The default is 2. Enter 0 to disable this option. Bypassed zones are automatically reset when the area they are assigned to is disarmed. All 24-hour zones are reset when any area of the system is disarmed. A Bypass report is sent to the receiver if Bypass Reports is set to Yes. |
Reset Swinger Bypass
RST SBYP NO YES |
NO (default) — Disable this option. YES — Reset the automatically bypassed zone if it remains in a normal condition for 1 hour after being bypassed. A report of the automatic reset is sent to the receiver if Bypass Reports is set to Yes. |
Zone Activity Hours
ZN ACTY HRS: 0 |
This option monitors activity for a person living alone. Enter the number of hours (0-9) that can elapse without a disarmed zone being tripped before a message is sent to the receiver. The default is 0, which disables this option. When the system is disarmed, the activity timer begins counting down. Each time activity occurs, the timer restarts. Before the timer expires, the keypad sounds a tone and displays PRESS ANY KEY, which allows the user to restart the activity timer. The tone duration is determined by the number of seconds programmed for Entry Delay 2. |
Request Time Change
REQUEST TIME CHG NO SCS SCW NTP |
This option allows the panel to request automatic time changes from SecureCom Wireless or the DMP SCS-1R or SCS-VR Receiver on Path 1. For the SCS receiver to send time changes, program it to send and receive time change updates from the network automation computer at least every 24 hours.
|
NTP URL
NTP URL: |
Enter the NTP URL. |
Daylight Saving Time
DST? NO YES |
NO (default) — Do not observe Daylight Saving Time. YES — Observe Daylight Saving Time. |
Hours from GMT
HRS FROM GMT: 6 |
Enter the number (0-23) that indicates the difference between the Greenwich Mean Time (GMT) and where the panel is located. The default is 6. See GMT Time Zones. |
Latch Supervisory Zones
LATCH SV NO YES |
YES (default) — Enable latch Supervisory zone alarms on the keypad to display until a sensor reset is performed. NO — Automatically clear Supervisory zone alarms from the keypad display when the zone restores to a normal condition. |
Programming Language
PROG LANGUAGE Primary Language
PRI LANG: ENGLISH ENG SPN FRN CZE GRE DUT Secondary Language
PRI LANG: ENGLISH ENG SPN FRN CZE GRE DUT |
Press CMD to select one of the following primary programming menu languages:
When a secondary programming language is chosen, the installer is prompted to choose the programming language. If this menu is set to None, the option to choose a language does not display, Select one of the following secondary programming menu languages:
|
User Language
USER LANGUAGE Primary Language
PRI LANG: ENGLISH ENG SPN FRN CZE GRE DUT Secondary Language
PRI LANG: ENGLISH ENG SPN FRN CZE GRE DUT |
Press CMD to select one of the following user menu languages:
When a secondary user language is chosen, the user is prompted to choose the language that displays in the User Menu and Status List when they access the User Menu. If this feature is set to None, the option to choose a language does not display. Select one of the following secondary programming menu languages:
|
Bypass Limit
BYPASS LIMIT: 0 |
Enter the maximum number of zones (0-8) that can be bypassed in any single area when that area is being armed at a keypad. The default is 0, which disables this feature. If the number of zones that are not in a normal state or are already bypassed exceeds this limit, the area cannot be armed and Arming Stopped displays. |
Wireless House Code
WIRELESS
|
Enter a house code from 1 to 50 to allow the DMP panel, receiver, and transmitters to communicate with one another. The default is 0, which means no wireless system is being used. The receiver listens for signals from transmitters that have a matching house code and programmed serial number. After you change the house code, allow up to 2 minutes for the transmitters to learn the new code and resume normal operation. |
Detect Wireless Jamming
DETECT WIRELESS JAMMING: NO YES |
NO (default) — Disable jamming messages. YES — Enable jamming messages to display in the Status List. When the wireless receiver detects jamming, a jammed trouble (when disarmed) or jammed alarm (when armed) message displays in the Status List and is sent to the monitoring center. |
1100 Series Wireless Encryption
1100 ENCRYPTION
|
Wireless encryption allows the panel to communicate with encrypted 1100 Series wireless devices.
|
Wireless Passphrase
1100 PASSPHRASE ****** |
📍 Displays if Wireless Encryption is All or Both. Enter a passphrase to support encrypted 1100 Series wireless devices. The passphrase is an 8-digit hexadecimal number that determines the system’s encryption key. |
Trouble Audible Annunciation
TRBL AUDIBLE: DAY |
This feature allows you to choose when trouble audibles annunciate from the keypad. This also includes Battery Trouble, Panel Tamper, and other system troubles. DAY (default) — Enable annunciation from 9 AM to 9 PM. ANY — Enable annunciation anytime. MIN — Enable annunciation for only Fire and Supervisory zones from 9 AM to 9 PM, |
Enable Keypad Panic Keys
KEYPAD PANIC KEYS
|
This feature allows the panic key operation selected at the keypad to send a Panic, Holdup, Emergency, or Fire message to the monitoring center. YES (default) — Enable two-button panic operation. NO — Disable this feature. |
Enhanced Zone Test
ENHANCED ZONE
|
NO (default) — Disable this option. YES — Allow enhanced zone test operation for the Walk Test, Panic Test, and Burglary Zone Test in the User Menu. See Test the System. Enhanced zone operation enables the following options:
|
Keypad Armed LED
KEYPAD ARMED LED
|
ALL (default) — Require all keypad display areas to arm before the keypad Armed LED turns on. ANY — Turn on the keypad Armed LED when any keypad display area armed. |
Allow Own User Code Change
ALLOW OWN USER CODE CHG? NO YES |
NO (default) — Leave this option disabled. YES — Allow users without user code authority to change their own user codes. When enabled, the User Code option in the User Menu displays USER CODE ****** at the keypad to allow users to change their own codes. |
Panic Supervision
PANIC SUPERVISION
|
NO — Disable this option. YES — Enable 30-day supervision for the 1144 Series Key Fob. This feature allows a lost key fob or one with a dead battery to be identified as a missing transmitter by the monitoring center’s host automation system without requiring a Supervision Time to be programmed in Zone Information. The key fob automatically sends a supervision message to the receiver every 4 hours, which resets the 30-day countdown timer for the key fob serial number. If the 30-day timer expires, the receiver sends a Zone Missing message to the host automation system. |
Weather Zip Code
ENTER WEATHER
|
This feature enables the keypad to display local U.S.A weather updates. Enter your zip code to use this option. The default is 0, which disables this option. If you are using a 7800 or 8800 Series Keypad, the current weather conditions and the next day’s forecast display as graphics on the main screen. All other DMP keypads display the weather information in the Status List. |
-
When you are finished, continue programming additional menus as needed, or press CMD until STOP displays, then press any select key or area to save the panel programming.
Program the Panel in Dealer Admin
Before You Begin
-
Verify the panel is connected to network
-
Log in to Dealer Admin.
-
Go to Customers, then select the System Name.
-
Go to Programming > System Options.
-
Configure the following options as needed:
|
Dealer Admin Field |
Description |
|---|---|
Instant Arming
|
Toggle ON to allow INSTANT to display on the arming keypad for selecting during the exit countdown delay when arming fewer than all system areas. When INSTANT is selected, entry and exit delays for the areas being armed are ignored. Entry delays for previously armed areas are not affected. Toggle OFF to disable this option. |
Closing Wait
|
Toggle ON to display ONE MOMENT… at the keypad while waiting for an acknowledgement from the receiver before arming the selected areas and performing a Bell Test (if selected). Exit delays begin after the Closing Wait. Toggle OFF to disable this option. |
Entry Delay 1
Entry Delay 2
Entry Delay 3
Entry Delay 4
|
Enter the number of seconds (30-250) for the Entry Delay time for all Exit type zones. When an armed Exit zone is faulted, the keypad prewarn tone sounds. Keypads programmed to prewarn for that zone display ENTER CODE:- and the zone name causing the Entry Delay. Note: For UL installation's, the combined Transmit Delay (Abort Window) and Entry Delay cannot exceed 1 minute. |
Cross Zone Time
|
Enter the number of seconds (4-240) allowed between zone faults. The default is 4. Enter 0 to disable this option. When zones are cross-zoned, ensure the same zone or a second cross-zoned zone faults within the programmed time for an Alarm report for both zones to send to the receiver. If the Cross Zone time expires without the second zone faulting, only a zone fault from the first zone is reported. See Cross Zoning. |
Zone Retard Delay
|
Enter the retard delay time (1-250 seconds) for Fire, Supervisory, Auxiliary 1, Auxiliary 2, Arming, Holdup, and Panic type zones. The default is 10 seconds. Enter 0 to disable this option. This delay only applies when a zone is shorted. The zone needs to remain shorted for the entire delay period before the panel recognizes the fault. |
Power Fail Delay
|
Enter the number of hours (1-15) AC power can be off before an AC Power Failure report is sent to the receiver. The default is 1 hour. Enter 0 to disable this option. |
Swinger Bypass Trips
|
Enter the number of times (1-6) a zone can enter an Alarm or Trouble condition within 1 hour before being automatically bypassed. The default is 2. Enter 0 to disable this option. Bypassed zones are automatically reset when the area they are assigned to is disarmed. All 24-hour zones are reset when any area of the system is disarmed. A Bypass report is sent to the receiver if Bypass Reports is set to Yes. |
Reset Swinger Bypass
|
Toggle ON to reset the automatically bypassed zone if it remains in a normal condition for 1 hour after being bypassed. A report of the automatic reset is sent to the receiver if Bypass Reports is set to Yes. Toggle OFF to disable this option. |
Zone Activity Hours
|
This option monitors activity for a person living alone. Enter the number of hours (0-9) that can elapse without a disarmed zone being tripped before a message is sent to the receiver. The default is 0, which disables this option. When the system is disarmed, the activity timer begins counting down. Each time activity occurs, the timer restarts. Before the timer expires, the keypad sounds a tone and displays PRESS ANY KEY, which allows the user to restart the activity timer. The tone duration is determined by the number of seconds programmed for Entry Delay 2. |
Update Time With
|
This option allows the panel to request automatic time changes from SecureCom Wireless or the DMP SCS-1R or SCS-VR Receiver on Path 1. For the SCS receiver to send time changes, program it to send and receive time change updates from the network automation computer at least every 24 hours.
|
NTP Server URL
|
Enter the NTP URL. |
Observe DST
|
Toggle ON to observe Daylight Saving Time. Toggle OFF to disable this option. |
Hours from GMT
|
Enter the number (0-23) that indicates the difference between the Greenwich Mean Time (GMT) and where the panel is located. The default is 6. See GMT Time Zones. |
Latched Supervisory Zones
|
Toggle ON to enable latched Supervisory zone alarms on the keypad to display until a sensor reset is performed. Toggle OFF to automatically clear Supervisory zone alarms from the keypad display when the zone restores to a normal condition. |
Primary Programming Language
|
Select one of the following primary programming menu languages:
|
Secondary Programming Language
|
When a secondary programming language is chosen, the installer is prompted to choose the programming language. If this menu is set to None, the option to choose a language does not display, Select one of the following secondary programming menu languages:
|
Primary User Language
|
Select one of the following user menu languages:
|
Secondary User Language
|
When a secondary user language is chosen, the user is prompted to choose the language that displays in the User Menu and Status List when they access the User Menu. If this feature is set to None, the option to choose a language does not display. Select one of the following secondary programming menu languages:
|
Bypass Limit
|
Enter the maximum number of zones (0-8) that can be bypassed in any single area when that area is being armed at a keypad. The default is 0, which disables this feature. If the number of zones that are not in a normal state or are already bypassed exceeds this limit, the area cannot be armed and Arming Stopped displays. |
Wireless House Code
|
Enter a house code from 1 to 50 to allow the DMP panel, receiver, and transmitters to communicate with one another. The default is 0, which means no wireless system is being used. The receiver listens for signals from transmitters that have a matching house code and programmed serial number. After you change the house code, allow up to 2 minutes for the transmitters to learn the new code and resume normal operation. |
Detect Wireless Jamming
|
Toggle ON to enable jamming messages to display in the Status List. When the wireless receiver detects jamming, a jammed trouble (when disarmed) or jammed alarm (when armed) message displays in the Status List and is sent to the monitoring center. Toggle OFF to disable jamming messages. |
Trouble Audibles
|
This feature allows you to choose when trouble audibles annunciate from the keypad. This also includes Battery Trouble, Panel Tamper, and other system troubles. Day (default) — Enable annunciation from 9 AM to 9 PM. Any — Enable annunciation anytime. Min — Enable annunciation for only Fire and Supervisory zones from 9 AM to 9 PM. |
Enable Keypad Panic Keys
|
This feature allows the panic key operation selected at the keypad to send a Panic, Holdup, Emergency, or Fire message to the monitoring center. Toggle ON to enable two-button panic operation. Toggle OFF to disable this feature. |
Enhanced Zone Test
|
Toggle ON to allow enhanced zone test operation for the Walk Test, Panic Test, and Burglary Zone Test in the User Menu. See Test the System. Enhanced zone operation enables the following options:
Toggle OFF to disable this option. |
Keypad Armed LED
|
All — Require all keypad display areas to arm before the keypad Armed LED turns on. Any — Turn on the keypad Armed LED when any keypad display area armed. |
Allow Own User Code Change
|
Toggle ON to allow users without user code authority to change their own user codes. When enabled, the User Code option in the User Menu displays USER CODE ****** at the keypad to allow users to change their own codes. Toggle OFF to disable this option. |
Panic Supervision
|
Toggle ON to enable 30-day supervision for the 1144 Series Key Fob. This feature allows a lost key fob or one with a dead battery to be identified as a missing transmitter by the monitoring center’s host automation system without requiring a Supervision Time to be programmed in Zone Information. The key fob automatically sends a supervision message to the receiver every 4 hours, which resets the 30-day countdown timer for the key fob serial number. If the 30-day timer expires, the receiver sends a Zone Missing message to the host automation system. Toggle OFF to disable this option. |
Weather Zip Code
|
This feature enables the keypad to display local U.S.A weather updates. Enter your zip code to use this option. The default is 0, which disables this option. If you are using a 7800 Series Keypad, the current weather conditions and the next day’s forecast display as graphics on the main screen. All other DMP keypads display the weather information in the Status List. |
1100 Wireless Encryption
|
Wireless encryption allows the panel to communicate with encrypted 1100 Series wireless devices.
|
1100 Wireless Encryption Passphrase
|
📍 Displays if Wireless Encryption is All or Both. Enter a passphrase to support encrypted 1100 Series wireless devices. Dealer Admin automatically generates an 8-digit hexadecimal passphrase that determines the system’s encryption key. |
-
When you are finished, select one of the following options:
-
-
If you are finished with all programming — Select Send All Changes at the top of the screen. This sends all programming changes to the panel.
-
If you are finished programming System Options only — Select the More icon
, then select Send System Options. This only sends system option programming changes to the panel.
-
Reference
Cross Zoning
Use caution when cross zoning devices. Ensure the Cross Zone Time is long enough for an intruder to trip both devices before the timer expires.
When a cross-zoned device trips, a FAULT report is sent to the receiver. If both cross-zoned devices trip within the configured Cross Zone Time, both zones send ALARM signals to the receiver.
If the Cross Zone Time is too short, an intruder may trip both devices after the timer expires, which causes only a FAULT report to be sent instead of ALARM signals.
Zone Activity Check Messages
Select the SUPV/TRBL receiver option in the Communication programming menu to send the following zone activity check messages:
-
S93 ALARM — User Activity Not Detected
-
S94 ALERT — Activity Check Enabled
-
S95 ALERT — Activity Check Disabled
GMT Time Zones
Note: Arizona, Hawaii, American Samoa, Guam, Puerto Rico, and the Virgin Islands do not observe Daylight Saving Time.
|
GMT |
City/Time Zone |
|---|---|
|
0 |
London, Monrovia, Lisbon, Dublin, Casablanca, Edinburgh |
|
1 |
Cape Verde Island, Azores |
|
2 |
Mid-Atlantic, Fernando de Noronha |
|
3 |
Buenos Aires, Georgetown, Brasilia, Rio de Janeiro |
|
4 |
Atlantic Time (Canada), Caracas, La Paz, Santiago |
|
5 |
Eastern Time (US, Canada), Bogota, Lima, Arequipa |
|
6 |
Central Time (US, Canada), Mexico City, Saskatchewan |
|
7 |
Mountain Time (US, Canada), Edmonton |
|
8 |
Pacific Time (US. Canada), Tijuana |
|
9 |
Alaska |
|
10 |
Hawaii |
|
11 |
Midway Island, Samoa |
|
12 |
Fiji, Marshall Island, Wellington, Auckland, Kwajalein, Kamchatka |
|
13 |
New Caledonia |
|
14 |
Guam, Sydney |
|
15 |
Tokyo, Seoul |
|
16 |
Hong Kong, Singapore |
|
17 |
Bangkok, Hanoi |
|
18 |
Dhaka, Almaty |
|
19 |
Islamabad, Karachi |
|
20 |
Abu Dhabi, Kazan |
|
21 |
Moscow, Bagdad |
|
22 |
Eastern Europe |
|
23 |
Rome, Paris, Berlin |