XR650 Installation and Programming Guide

Device Setup

This section allows you to configure the panel’s physical device configuration. You can install and address up to 16 supervised devices on the keypad bus. Additional devices can be added to the available LX-Buses. Programmable device types include Keypad, Door, Expander, Fire, 1100T, XR Panel, and V-PLEX.

Program the Panel at the Keypad

  1. Press 6653 (PROG), then CMD at the keypad to enter the PROGRAMMER menu.

  2. Press CMD until you see DEVICE SETUP, then press any select key or area.

  3. Configure the following options as needed:

Keypad Display

Description

Card Formats

CARD FORMATS

This feature allows you to program custom non-DMP cards.

Refer to the 734 Access Control Module Installation and Programming Guide for a chart of commonly used card formats and their defaults.

Format Number

FORMAT NO:

Enter the card format number (1-8).

Format Name

FORMAT NAME

Enter the card format name.

Wiegand Code Length

WIEGAND CODE
LENGTH: 26

When using a custom credential, enter the total number of bits (1-255) to be received in Wiegand code, including parity bits. The default is 26 bits.

Determine and program the starting position location and code length into the 734 Series module.

Site Code Position and Length

SITE CODE POS: 1
LEN: 8

Enter the site code start position (0-255) in the data string. The default is 1.

Enter the number of characters (1-16) the site code contains. The default is 8.

User Code Position and Length

USER CODE POS: 9
LEN: 16

Enter the user code start bit position (0-255). The default is 9.

Enter the number of user code bits (16-64). The default is 16.

Require Site Code

REQUIRE SITE CODE?
NO YES

NO — Disable this option.

YES — Enable a site code.

In addition to User Code verification, door access is only granted when any one site code programmed at the SITE CODE ENTRY option matches the site code received in the Wiegand string.

Site Code 1-8

SITE CODE 1:
-

734 Series Modules — Program up to 8 eight-digit site codes. Any previously programmed site codes display. Dashes represent blank site codes. The default is blank.

734N/734N-POE Modules Only — Program up to 8 eight-digit site codes. Any previously programmed site codes display. The default for Site Code 1 is 127. The default for site codes 2-8 are blank.

To delete an existing site code, press any select key or area. Enter a new site code or press CMD to leave the option blank and continue to the next site code. Repeat these steps to change, delete, or add up to 8 site codes.

Number of User Code Digits

NO OF USER CODE
DIGITS:

Enter a user code digit length (4-12). The number should match the user code number length used by the panel. The default is 5.

Any selection above 5 digits requires entry of the custom card definitions with custom site and user code positions for the Wiegand string. When searching the bit string for the user code, the digits are identified and read from left to right

Device Number

DEVICE NO:
-

Note: Wireless keypads and network door controllers are unable to occupy address 1.

Enter the address of the device you are programming. The available addresses are 1-16 on the panel keypad bus and 500-599 on the LX-Bus.

The valid range for Keypad and Expander devices is 1-16 on the keypad bus. The valid range for Door devices is 1-16 on the keypad bus and 501-961 on the AX-Bus.

See the Device Addresses and 734 Zone Numbers chart for available addresses.

See 734 Modules AX-Bus Operation for more information on AX-Bus functionality.

Device Name

*UNUSED*

Enter a device name up to 32 alphanumeric characters.

To remove a device from the system, delete the device name by pressing any select key or area, then select CMD.

Device Type (Keypad Bus Addresses)

TYPE: KEYPAD

DOOR KPD EXP TLR

PNL

Device Type (AX-Bus Addresses)

TYPE: KEYPAD

DOOR VPX EXP PNL

Select one of the following device types for the selected device number.

  • DOOR — Access control device that is a keypad using door strike functions or an access control module. Devices with an address higher than 16 are automatically assigned as a Door device type.

  • KEYPAD — Non-fire, non-access keypad.

  • EXPANDER — Zone expansion module

  • VPX — V-Plex device. The valid zones for VPX devices are 501, 601, 701, 801, and 901.

  • TLR — 1100T Wireless Translator

  • PNL — Secondary XR panel

1100T

1100T? NO YES

TRANSMITTER
SERIAL #: XXXXXXXX

1100T FREQ:
HWL 2GIG INT DSC

📍 Displays if Device Type is TLR

The 1100T allows you to use compatible non-DMP (competitor) wireless with an XR650 panel.

NO (default) — Disable this option.

YES — Use an 1100T Wireless Translator.

Valid device numbers are 2-16. An 1100T can only be programmed on keypad addresses. One 1100T Translator is programmable per XR650 panel.

Enter the 1100T serial number, then select one of the following communication frequencies:

  • HWL (default) — Honeywell

  • 2GIG

  • INT — Interlogix

  • DSC

If an 1100T is programmed, complete the following steps:

  1. At ZONE INFORMATION, go to COMP WLS? (Competitor Wireless), then select YES.

  2. Enter the Competitor Wireless Serial Number at COMP WLS SRL #.

Device Communication Type

DEVICE COMM TYPE
KPD-BUS AX-BUS

DEVICE COMM TYPE
KPD WLS NET

KYPD-BUS — Select this option for devices connected to the keypad bus.

AX-BUS — Select this option for addresses 501-964.

WLS — Enable wireless communication for the device.

NET — Select this option for devices that communicate over a network connection.

If the panel uses a hardwired network connection, it supports up to 15 network keypads.

Note: You can only enter the Programmer menu or disable the Programming Port on a hardwired keypad when connected to the keypad bus on an XR650 panel.

Encryption

ENCRYPTED?
NO YES

📍 Displays if Device Type is a Door on the
AX-Bus

Note: When encryption is enabled for a single device on an AX-Bus, ensure all devices on that bus are encrypted.

NO (default) — Disable this option.

YES — Enable encryption for this device.

XR Panel Serial Number

XR PANEL
SERIAL #:

📍 Displays if Device Type is XR Panel

Enter the 8-digit serial number for the secondary XR panel.

Supervision Time

SUPERVSN TIME: 240

SELECT MINUTES:
0 60 240

📍 Displays if Device Type is Keypad and Device Communication Type is Wireless

Select the supervision time required for the device. The default is 240 minutes. Enter 0 to configure an unsupervised wireless keypad.

The device checks in at least once during this time or if a missing condition is indicated for that device.

Access Areas

ACCESS AREAS

📍 Displays if Device Type is Door

To select an area, enter the area number (1-99) using the digit keys on the keypad. When an area is selected, an asterisk appears next to the area number. Enter the number again to deselect the area.

Note: Users should have matching access area numbers assigned to their code to receive a door access at this device.

Egress Areas

EGRESS AREAS

📍 Displays if Device Type is Door

Use this option to detect Anti-Passback violations. Anti-Passback requires a user to properly exit (egress) an area they have previously accessed. If users do not exit through the proper card reader location, they are not granted access on their next attempts.

To select an area, enter the area number (1-99) using the digit keys on the keypad. When an area is selected, an asterisk appears next to the area number. Enter the number again to deselect the area.

Display Areas

DISPLAY AREAS

📍 Displays if Device Type is Door or Keypad

This option allows the panel’s burglary activities to segment so that only specific areas and their associated operations appear at a particular keypad. This allows area control from specific keypads, as well as zone annunciation assigned to those areas.

To select an area, enter the area number (1-99) using the digit keys on the keypad. When an area is selected, an asterisk appears next to the area number. Enter the number again to deselect the area.

When Display Areas is left defaulted (all areas selected), Menu Display, and Status List items determine if zone alarms and troubles display at this device, regardless of area assignment. All system areas may be armed and disarmed from this device.

See Display Areas Operation for more information.

Strike Time

STIKE TIME: 5

📍 Displays if Device Type is Door

Enter a door access time (1-250 seconds) when a keypad or access control device relay is activated. The default is 5 seconds. Enter 0 to activate the device relay with a toggle action.

Magnetic locks or electric door strikes are connected to the relay and released for the length of the strike time. This allows the user to activate or deactivate the device relay each time a valid user code is entered. The device relay is activated or deactivated until a user code is entered again.

Strike Delay

STRIKE DELAY: 0

📍 Displays if Device Type is Door

Enter the number of minutes (0-9) to delay a door strike after a valid code is entered or a card read occurs. The default is 0.

When a valid code or card read is received, the activation of the door strike is delayed for the number of minutes programmed. The standard door strike message is sent to the monitoring center receiver.

During the delay, all subsequent codes entered or cards presented to the reader for a door strike are ignored and no record of the attempt is stored.

Fire Exit

FIRE EXIT NO YES

📍 Displays if Device Type is Door

NO (default) — Disable this option.

YES — Allow the door access relay at this address to release when Fire panic keys are pressed or a Fire zone alarm is in the Status List.

The relay is reset when a Sensor Reset is performed to remove all Fire zone alarms from the Status List.

Public Door

PUBLIC DR NO YES

📍 Displays if Device Type is Door

NO (default) — Disable this option.

YES — Allow the device to send a lock command when a lockdown is initiated through the User Menu, a remote command, or a Panic or Holdup zone programmed to initiate a lockdown.

Output Group

OUTPUT GROUP NO YES

📍 Displays if Device Type is Door

NO (default) — Disable this option.

YES — Allow the output group (relays) assigned to the user group to turn ON when the device relay is activated for the programmed Strike Time.

See Groups for more information.

Schedule Override

OVERRIDE NO YES

📍 Displays if Device Type is Door

NO (default) — Disable this option.

YES — Allow the schedule to be overridden by the system’s armed condition.

This allows the door schedule’s ON time to be ignored when all areas assigned to Access Areas for the device are armed. If any areas becomes disarmed after the door’s scheduled ON time, the device output turns on.

A door output that is on during a disarmed period automatically turns off when all Access Areas assigned to the device become armed, even if the scheduled OFF time has not been reached.

This feature can be used to keep doors locked when a factory opens late or is forced to close early.

Note: When Schedule Override is set to Yes and there are not areas programmed in Access Areas, the door schedule for that device does not work. Set Schedule Override to No or enter an area number in Access Areas.

Auto Force Arm Device

AUTO FORCE ARM DEVICE?
NO YES

📍 Displays if Device Type is Door or Keypad

NO (default) — Disable this option. The user is prompted to select areas and choose to force arm or bypass at arming and disarming.

YES — Allow all Display Areas assigned to the device to automatically arm and force arm faulted zones at arming.

If Closing Code is set to Yes, only the matching areas between the Display Areas and the user code’s authorized areas arm. When Yes is selected, all matching areas assigned to the user code and to the device are automatically disarmed.

Door Real-Time Status

DOOR REAL-TIME STATUS?
NO YES

📍 Displays if Device Type is Door

NO (default) — Disable this option.

YES — Send real-time door status messages to Entré, the API connection, and Dealer Admin accounts that are reporting for the device. Messages are sent when the panel turns the door relay on or off.

Send Door Forced

SEND DOOR FORCED MESSAGE?
NO YES

📍 Displays if Device Type is Door

NO (default) — Disable this option.

YES — Send the Forced Open (FO) real-time door status messages to Entré, the API connection, and Dealer Admin reporting when the door relay is off but the door zone has transitioned from its normal state.

734 Options

Program 734 Options

PROGRAM 734 OPTIONS?
NO YES

📍 Displays if Device Type is Door

NO (default) — Do not program 734 options.

YES — Program a 734.

Reader Protocol Type

READER PROTOCOL TYPE
WIEGAND

READER PROTOCOL:
WIEGAND OSDP

Note: To use the OSDP programming fields below, 734 Access Control Module firmware Version 108 is required.

Select WIEGAND (default) or OSDP for the card reader protocol type.

OSDP LED Control

LED CONTROL
NO YES

📍 Displays if Reader Protocol Type is OSDP

NO (default) — Disable this option.

YES — Enable reader LED operation.

OSDP Passphrase

OSDP PASSPHRASE
***************

📍 Displays if Reader Protocol Type is OSDP

The OSDP passphrase is programmed into the OSDP reader and is used to establish 128-bit AES encrypted two-way communication between the reader and panel.

Enter a passphrase up to 16 alphanumeric characters. These characters are visible until CMD is pressed.

Record this passphrase and store it in a secure location away from the panel and reader. After the passphrase is bonded to the panel, the passphrase cannot be changed in the reader or retrieved from XR programming.

OSDP Buzzer Control

BUZZER CONTROL
NO YES

📍 Displays if Reader Protocol Type is OSDP

NO (default) — Disable this option.

YES — Enable built-in reader annunciation.

OSDP Tamper Control

TAMPER CONTROL
NO YES

📍 Displays if Reader Protocol Type is OSDP

NO (default) — Disable this option.

YES — Enable tamper control for the panel.

To test the OSDP tamper control, ensure the OSDP reader’s tamper is no longer satisfied and observe the tamper message at the keypad and the messages sent to the monitoring center.

Activate Zone 2 Bypass

ACTIVATE ZONE 2 BYPASS?
NO YES

NO (default) — Disable this option. Allow standard zone operation on zone 2.

YES — Activate the bypass option.

If the door being released by the 734 is protected (contact installed), you can provide a programmable bypass entry/exit time by connecting its contact wiring to zone 2 on the 734. When the onboard Form C relay activates and the user opens the door connected to zone 2, the zone bypasses for the number of seconds programmed in Zone 2 Bypass Time to allow the user to enter or exit.

If zone 2 does not restore (door closed) within the programmed bypass time, the 734 piezo pulses during the last ten seconds. If the zone does not restore before the programmed time, the 734 ends the bypass and indicates the open or short zone condition to the panel.

Zone 2 Bypass Time

ZONE 2 BYPASS TIME: 40

Enter the number of bypass seconds (20-250) that can elapse before the bypass timer expires. The default is 40 seconds.

If the door remains open when the timer expires, a zone open/short is sent to the panel for zone 2.

Relock on Zone 2 Change

RELOCK ON ZONE 2 CHANGE?
NO YES

NO (default) — Disable this option. Leave the relay on for the door access time when zone 2 restores.

YES — Turn the 734 relay off and relock the door when zone 2 changes states.

Activate Zone 3 Request to Exit

ACTIVATE ZONE 3 REX?
NO YES

NO (default) — Disable this option. Allow standard zone operation on zone 3.

YES — Activate the zone 3 REX option.

See Zone 3 Additional Operation for more information.

Zone 3 REX Strike Time

ZN 3 REX STRIKE TIME: 5

Enter the number of REX seconds (5-250) to elapse. The default is 5 seconds.

Activate Onboard Speaker

ACTIVATE ONBOARD SPEAKER?
NO YES

NO (default) — Turn off the piezo for all operations. This does not affect remote annunciator open collector (RA) operation.

YES — Enable the onboard piezo speaker for local annunciation.

Card Options

CARD OPTIONS
DMP CUSTOM ANY

  • DMP (default) — Allow only the DMP card format for access.

  • CUSTOM — Disable DMP format and program slots 1-8 as needed. The format programmed into slot 1 is the default format. If a card with an unrecognized format is programmed when adding a credential, the card is read in the format that is programmed in slot 1. To restrict card reads to specific formats, only program slots 2-8.

  • ANY — Allow all Wiegand card reads to activate the door strike relay. The relay is activated for the length of time programmed in Zone 3 REX Time. No user code information is sent to the panel.

Require Site Code

REQUIRE SITE CODE
NO YES

📍 Displays if Card Options is DMP

NO (default) — Disable this option.

YES — Use a site code.

In addition to user code verification, door access is only granted when any one site code programmed at Site Code Entry matches the site code received in the Wiegand string.

No Communication With Panel

NO COMM WITH PNL
OFF SITE ANY ON

LAST

This feature defines the relay action when communication with the panel has not occurred for approximately ten seconds. Select one of the following options:

  • OFF (default) — The relay is always off. The relay does not turn on when any Wiegand string is received. This does not affect any REX operation.

  • SITE — Accept the site code. Door access is granted when the Wiegand site code string received matches any site code programmed at Site Code Entry. See Require Site Code for more information.

  • ANY — Door access is granted when any Wiegand string is received.

  • ON — The relay is always on.

  • LAST — The relay remains in the same state and does not change when communication is lost.

  1. When you are finished, continue programming additional menus as needed, or press CMD until STOP displays, then press any select key or area to save the panel programming.

Program the Panel in Dealer Admin

Before You Begin

  • Verify the panel is connected to network

  • Log in to Dealer Admin.

  1. Go to Customers, then select the System Name.

  2. Go to Programming > Device Setup.

Note: To program Card Formats in Dealer Admin, go to Programming > Card Formats.

  1. Configure the following options as needed:

Dealer Admin Field

Description

Device Number

Note: Wireless keypads and network door controllers are unable to occupy address 1.

Enter the address of the device you are programming. The available addresses are 1-16 on the panel keypad bus and 500-599 on the LX-Bus.

The valid range for Keypad and Expander devices is 1-16 on the keypad bus. The valid range for Door devices is 1-16 on the keypad bus and 501-961 on the AX-Bus.

See the Device Addresses and 734 Zone Numbers chart for available addresses.

See 734 Modules AX-Bus Operation for more information on AX-Bus functionality.

Device Name

Enter a device name up to 32 alphanumeric characters.

Device Type

Select one of the following device types for the selected device number.

  • Door — Access control device that is a keypad using door strike functions or an access control module. Devices with an address higher than 16 are automatically assigned as a Door device type.

  • Keypad — Non-fire, non-access keypad.

  • Zone Expander — Zone expansion module

  • V-Plex — V-Plex device. The valid zones for VPX devices are 501, 601, 701, 801, and 901.

  • 1100T — 1100T Wireless Translator

  • XR Panel — Secondary XR panel

Device Communication Type

Keypad Bus — Select this option for devices connected to the keypad bus.

AX-Bus — Select this option for addresses 501-964.

Wireless— Enable wireless communication for the device.

Network — Select this option for devices that communicate over a network connection.

Panel Communication Type

Available Network Keypads (Including Wi-Fi Keypads)

Hardwired network

15 network keypads

Wi-Fi only (763 Module)

0 network keypads

Display Areas

📍 Displays if Device Type is Door or Keypad

This option allows the panel’s burglary activities to segment so that only specific areas and their associated operations appear at a particular keypad. This allows area control from specific keypads, as well as zone annunciation assigned to those areas.

Enter the area number (1-99).

When Display Areas is left defaulted (all areas entered), Menu Display, and Status List items determine if zone alarms and troubles display at this device, regardless of area assignment. All system areas may be armed and disarmed from this device.

See Display Areas Operation for more information.

Auto Force Arm Device

📍 Displays if Device Type is Door or Keypad

Toggle OFF to disable this option. The user is prompted to select areas and choose to force arm or bypass at arming and disarming.

Toggle ON to allow all Display Areas assigned to the device to automatically arm and force arm faulted zones at arming.

If Closing Code is toggled ON, only the matching areas between the Display Areas and the user code’s authorized areas arm. When enabled, all matching areas assigned to the user code and to the device are automatically disarmed.

1100T Wireless Frequency

📍 Displays if Device Type is 1100T

Select one of the following communication frequencies for the 1100T:

  • HONEYWELL

  • 2GIG

  • INTERLOGIX

  • DSC

If an 1100T is programmed, complete the following steps:

  1. Go to Programming > Zone Information > Competitor Wireless. Toggle ON the option.

  2. Enter the Competitor Wireless Serial Number.

Serial Number

Enter the device serial number.

Supervision Time

📍 Displays if Device Type is Door, Keypad, or 1100T and Device Communication Type is Wireless

Select the supervision time required for the device. The default is 240 minutes. Enter 0 to configure an unsupervised wireless keypad.

The device checks in at least once during this time or if a missing condition is indicated for that device.

Access Areas

📍 Displays if Device Type is Door

Enter the area number (1-99) using the digit keys on the keypad.

Note: Users should have matching access area numbers assigned to their code to receive a door access at this device.

Egress Areas

📍 Displays if Device Type is Door

Use this option to detect Anti-Passback violations. Anti-Passback requires a user to properly exit (egress) an area they have previously accessed. If users do not exit through the proper card reader location, they are not granted access on their next attempts.

Enter the area number (1-99) using the digit keys on the keypad.

Strike Time

📍 Displays if Device Type is Door

Enter a door access time (1-250 seconds) when a keypad or access control device relay is activated. The default is 5 seconds. Enter 0 to activate the device relay with a toggle action.

Magnetic locks or electric door strikes are connected to the relay and released for the length of the strike time. This allows the user to activate or deactivate the device relay each time a valid user code is entered. The device relay is activated or deactivated until a user code is entered again.

Strike Delay

📍 Displays if Device Type is Door

Enter the number of minutes (0-9) to delay a door strike after a valid code is entered or a card read occurs. The default is 0.

When a valid code or card read is received, the activation of the door strike is delayed for the number of minutes programmed. The standard door strike message is sent to the monitoring center receiver.

During the delay, all subsequent codes entered or cards presented to the reader for a door strike are ignored and no record of the attempt is stored.

Fire Exit Release

📍 Displays if Device Type is Door

Toggle OFF to disable this option.

Toggle ON to allow the door access relay at this address to release when Fire panic keys are pressed or a Fire zone alarm is in the Status List.

The relay is reset when a Sensor Reset is performed to remove all Fire zone alarms from the Status List.

Public Door

📍 Displays if Device Type is Door

Toggle OFF to disable this option.

Toggle ON to allow the device to send a lock command when a lockdown is initiated through the User Menu, a remote command, or a Panic or Holdup zone programmed to initiate a lockdown.

Encrypted

📍 Displays if Device Type is a Door on the
AX-Bus

Note: When encryption is enabled for a single device on an AX-Bus, ensure all devices on that bus are encrypted.

Toggle OFF to disable this option.

Toggle ON to enable encryption for this device.

Output Group

📍 Displays if Device Type is Door

Toggle OFF to disable this option.

Toggle ON to allow the output group (relays) assigned to the user group to turn ON when the device relay is activated for the programmed Strike Time.

See Groups for more information.

Schedule Override

📍 Displays if Device Type is Door

Toggle OFF to disable this option.

Toggle ON to allow the schedule to be overridden by the system’s armed condition.

This allows the door schedule’s ON time to be ignored when all areas assigned to Access Areas for the device are armed. If any areas becomes disarmed after the door’s scheduled ON time, the device output turns on.

A door output that is on during a disarmed period automatically turns off when all Access Areas assigned to the device become armed, even if the scheduled OFF time has not been reached.

This feature can be used to keep doors locked when a factory opens late or is forced to close early.

Note: When Schedule Override is set to Yes and there are not areas programmed in Access Areas, the door schedule for that device does not work. Set Schedule Override to No or enter an area number in Access Areas.

Door Real-Time Status

📍 Displays if Device Type is Door

Toggle OFF to disable this option.

Toggle ON to send real-time door status messages to Entré, the API connection, and Dealer Admin accounts that are reporting for the device. Messages are sent when the panel turns the door relay on or off.

Send Door Forced

📍 Displays if Device Type is Door

Toggle OFF to disable this option.

Toggle ON to send the Forced Open (FO) real-time door status messages to Entré, the API connection, and Dealer Admin reporting when the door relay is off but the door zone has transitioned from its normal state.

Program 734 Options

📍 Displays if Device Type is Door

Toggle OFF to not program 734 options.

Toggle ON to program a 734.

734 Options

Reader Protocol

Note: To use the OSDP programming fields below, 734 Access Control Module firmware Version 108 is required.

Choose one of the following options for the card reader protocol type:

  • WIEGAND (default)

  • OSDP

  • None

OSDP Passphrase

📍 Displays if Reader Protocol is OSDP

The OSDP passphrase is programmed into the OSDP reader and is used to establish 128-bit AES encrypted two-way communication between the reader and panel.

Enter a passphrase up to 16 alphanumeric characters.

Record this passphrase and store it in a secure location away from the panel and reader. After the passphrase is bonded to the panel, the passphrase cannot be changed in the reader or retrieved from XR programming.

Activate Zone 2 Bypass

Toggle OFF to disable this option.

Toggle ON to activate the bypass option.

If the door being released by the 734 is protected (contact installed), you can provide a programmable bypass entry/exit time by connecting its contact wiring to zone 2 on the 734. When the onboard Form C relay activates and the user opens the door connected to zone 2, the zone bypasses for the number of seconds programmed in Zone 2 Bypass Time to allow the user to enter or exit.

If zone 2 does not restore (door closed) within the programmed bypass time, the 734 piezo pulses during the last ten seconds. If the zone does not restore before the programmed time, the 734 ends the bypass and indicates the open or short zone condition to the panel.

Zone 2 Bypass Time

Enter the number of bypass seconds (20-250) that can elapse before the bypass timer expires. The default is 40 seconds.

If the door remains open when the timer expires, a zone open/short is sent to the panel for zone 2.

Relock on Zone 2 Change

Toggle OFF to disable this option. Leave the relay on for the door access time when zone 2 restores.

Toggle ON to turn the 734 relay off and relock the door when zone 2 changes states.

Activate Zone 3 Request to Exit

Toggle OFF to disable this option. Allow standard zone operation on zone 3.

Toggle ON to activate the zone 3 REX option.

See Zone 3 Additional Operation for more information.

Zone 3 REX Strike Time

Enter the number of REX seconds (5-250) to elapse. The default is 5 seconds.

Activate Onboard Speaker

Toggle OFF to turn off the piezo for all operations. This does not affect remote annunciator open collector (RA) operation.

Toggle ON to enable the onboard piezo speaker for local annunciation.

Card Options

Select one of the following card options:

  • DMP (default) — Allow only the DMP card format for access.

  • Custom — Disable DMP format and program slots 1-8 as needed. The format programmed into slot 1 is the default format. If a card with an unrecognized format is programmed when adding a credential, the card is read in the format that is programmed in slot 1. To restrict card reads to specific formats, only program slots 2-8.

  • Any — Allow all Wiegand card reads to activate the door strike relay. The relay is activated for the length of time programmed in Zone 3 REX Time. No user code information is sent to the panel.

Require Site Code

📍 Displays if Card Options is DMP

Toggle OFF to disable this option.

Toggle ON to use a site code.

In addition to user code verification, door access is only granted when any one site code programmed at Site Code Entry matches the site code received in the Wiegand string.

User Code Digits

Enter a user code digit length (4-12). The number should match the user code number length used by the panel. The default is 5.

Any selection above 5 digits requires entry of the custom card definitions with custom site and user code positions for the Wiegand string. When searching the bit string for the user code, the digits are identified and read from left to right

No Communication With Panel

This feature defines the relay action when communication with the panel has not occurred for approximately ten seconds. Select one of the following options:

  • Off (default) — The relay is always off. The relay does not turn on when any Wiegand string is received. This does not affect any REX operation.

  • Site — Accept the site code. Door access is granted when the Wiegand site code string received matches any site code programmed at Site Code Entry. See Require Site Code for more information.

  • Any — Door access is granted when any Wiegand string is received.

  • On — The relay is always on.

  • Last — The relay remains in the same state and does not change when communication is lost.

OSDP Options

Send Device Setup, then Dealer Admin displays the connected reader information.

OSDP LED Control

Toggle OFF to disable this option.

Toggle ON to enable reader LED operation.

OSDP Buzzer Control

Toggle OFF to disable this option.

Toggle ON to enable built-in reader annunciation.

OSDP Tamper Control

Toggle OFF to disable this option.

Toggle ON to enable tamper control for the panel.

To test the OSDP tamper control, ensure the OSDP reader’s tamper is no longer satisfied and observe the tamper message at the keypad and the messages sent to the monitoring center.

  1. When you are finished, select one of the following options:

    • If you are finished with all programming — Select Send All Changes at the top of the screen. This sends all programming changes to the panel.

    • If you are finished programming Device Setup only — Select the More icon menu.png , then select Send Device Setup. This only sends device programming changes to the panel.

Reference

734 Modules AX -Bus Operation

An AX-Bus operation is compatible with 734, 734N, and 734N-POE modules. Once a 734 address is programmed for the bus, the LX-Bus is automatically converted from a hardwired zone expansion bus to a hardwired AX-Bus, and the bus begins to operate in the following ways:

  • Each 734 module provides one door relay and four protection zones to connect switches, such as door and window contacts.

  • 16 doors of access can be programmed per AX-Bus to a maximum of eighty 734 modules. See the table below for available addresses.

  • Any unused AX-Bus zone numbers can be programmed as wireless zones. Hardwired zone expansion modules, such as the 711, 714, and 715-16, are incompatible with bus operation and cannot be used.

  • Device Setup programming for AX-Bus addresses are automatically programmed as door types. Device Type, Communication Type, and Display Areas are not shown. Only 734 module programming is shown.

Device Addresses and 734 Series Zone Numbers

Note: The 734E only communicates through the AX-Bus and does not use the keypad bus. When a 734E is programmed on a bus, all devices connected to that bus only operate if they are encrypted.

Addressable expanders and door controllers identify themselves to the control panel using their programmed address, which allows the panel to uniquely identify each device. The device address determines the zone, output, or door controller numbers assigned during programming.

Refer to the tables below and the device’s installation guide for addressing information.

Keypad Bus

Device Address

Zones

1

11-14

2

21-24

3

31-34

4

41-44

5

51-54

6

61-64

7

71-74

8

81-84

9

91-94

10

101-104

11

111-114

12

121-124

13

131-134

14

141-144

15

151-154

16

161-164

D = Device Address
Z = Zones

AX/LX-Bus

D

Z

D

Z

D

Z

D

Z

D

Z

501

501-504

601

601-604

701

701-704

801

801-804

901

901-904

505

505-508

605

605-08

705

705-708

805

805-808

905

905-908

509

509-512

609

609-612

709

709-712

809

809-812

909

909-912

513

513-516

613

613-616

713

713-716

813

813-816

913

913-916

517

517-520

617

617-620

717

717-720

817

817-820

917

917-920

521

521-524

621

621-624

721

721-724

821

821-824

921

921-924

525

525-528

625

625-628

725

725-728

825

825-828

924

925-928

529

529-532

629

629-632

729

729-732

829

829-832

929

929-932

533

533-536

633

633-636

733

733-736

833

833-836

933

933-936

537

537-540

637

637-640

737

737-740

837

837-840

937

937-940

541

541-544

641

641-644

741

741-744

841

841-844

941

941-944

545

545-548

645

645-648

745

745-748

845

845-848

945

945-948

549

549-552

649

649-652

749

749-752

849

849-852

949

949-952

553

553-556

653

653-656

753

753-756

843

853-856

953

953-956

557

557-560

657

657-660

757

757-760

857

857-860

957

957-960

561

561-564

661

661-664

761

761-764

861

861-864

961

961-964

*The 734E only communicates through the AX-Bus and does not use the keypad bus. When a 734E is programmed on a bus, all devices connected to that bus only operate if they are encrypted.

Display Areas Operation

Allowed User Actions

The user actions require the matching areas be enabled in Arm/Disarm areas option in Groups programming. When an area is selected, the following user actions are allowed:

  • Arming or disarming of the area(s) selected from the ARM or DISARM menu

  • Alarm Silence for the selected areas

  • Zone Bypass of zones assigned to the selected areas

  • Zone Monitor of zone assigned to the selected areas

  • Shift schedule changes allowed for the selected areas

  • Closing Check Schedule Extend allowed for the selected areas

  • Door Schedules changes allowed for devices that have matching area as defined in Device Access Areas

  • Door On/Off Menu operation allowed for devices that have matching area as defined in Device Access Areas

Allowed Status Displays

When an area is chosen, the following displays are allowed:

  • Armed Status of the selected areas

  • Zone alarms and troubles for burglary type zones (NT, DY, EX, A1, A2) assigned to the selected areas

  • Late to Close status of the selected areas

  • Zone Status (normal/fault) of zones that are assigned to the selected areas

Options and Actions Unaffected

The following options are not affected by the Display Areas operation. The User Code authority level controls access to the following items:

  • Sensor Reset Menu

  • Outputs On/Off Menu

  • System Status Menu

  • System Test/Panic Test

  • User Groups

  • Forgive Anti-Passback

  • Service Request

  • Set System Time and Date

  • Display Events

Note: 24-hour zones display at keypads based on Status List programming only

Zone 3 Additional Operation

Optionally, you can connect a PIR (or other motion sensing device) or a mechanical switch to zone 3 to provide REX capability to the system.

When Zone 3 shorts, the onboard Form C relay activates for the programmed number of seconds. During this time, the user can open the protected door to start the programmed bypass entry/exit timer. After the programmed number of seconds, the relay restores the door to its locked state.

The 734 provides a bypass-only option for REX on zone 3. When zone 3 opens from a normal state, only a bypass occurs, and the onboard relay does not activate. This bypass-only option uses two methods of REX:

  • The first REX device provides the programmed bypass entry/exit timer.

  • The second REX device, or manual device such as a door knob, unlocks the door.

An example of the bypass-only configuration is a door to an office that is locked 24 hours a day. Users pass a REX motion detector positioned by the door to begin the programmed exit timer. Within the programmed number of seconds, the user then manually activates a second device, such as a REX device or manual door knob, to unlock the door. If the door is opened after the programmed number of seconds, the zone goes into alarm.

Last updated: