This menu allows you to clear all or selected parts of panel programming back to the factory defaults.
Note: The INITIALIZATION menu is only available when programming from a keypad. In Dealer Admin, you can delete programming as needed.
-
Press 6653 (PROG), then CMD at the keypad to enter the PROGRAMMER menu.
-
Press CMD until you see INITALIZATION, then press any select key or area.
-
Configure the following options as needed:
|
Keypad Display |
Options |
|---|---|
Clear All Panel Memory
INIT ALL? NO YES |
NO - Leave existing programming intact. YES - Clear all memory. Reset the panel and reenter the PROGRAMMER menu to continue. |
Clear User Codes
CODES? NO YES |
NO - Leave existing codes intact. YES - Clear the user code and groups memory, and assign user code number 99 to the highest user number. |
Clear Schedules
SCHDS? NO YES |
NO - Leave existing schedules intact. YES - Clear all shift and output schedules. |
Clear Events Memory
EVENTS? NO YES |
NO - Leave existing events memory intact. YES - Clear the events memory. |
Clear Zone Information
ZONES? NO YES |
NO - Leave existing zone information intact. YES - Clear the zone information for all zones. |
Clear Area Information
AREAS? NO YES |
NO - Leave existing area information intact. YES - Clear all area information for all areas. |
Clear Output Information
OUTPUTS? NO YES |
NO - Leave existing output information intact. YES - Clear all programmed output names and any output cutoff assignments. |
Clear Communication and Remote Options
COM/RMT? NO YES |
NO - Leave existing communication and remote options intact. YES - Reset all communication and remote options programming to factory defaults. |
Set to Factory Defaults
DEFAULTS NO YES |
NO - Leave existing panel programming intact. YES - Reset panel programming back to factory default selections and clear all Device Setup, System Options, and Remote Options programming. It does not clear the panel’s event memory, zones, user code information, or schedules. |
-
When you are finished, continue programming additional menus as needed, or press CMD until STOP displays, then press any Select key or area to save the panel programming.