Note: To program a key fob, set the Wireless House Code in System Options to 1-50.
This section allows you to program 1144 Series Key Fobs. Zones 400-499 can be programmed as key fobs. See the 1144 Series Key Fob Installation Guide for more information.
To operate arming and disarming properly, ensure the key fob is assigned to a user number with appropriate area assignments. However, the user number does not have to exist at the time the key fob is programmed. The key fob user number can be added later.
Note: 1144 Series Key Fobs can also be programmed as 1-button or 2-button wireless Panic or Holdup zones. The available zone range is 500-999. Programming key fobs as panic zones requires 100XH Series Wireless Receivers Version 209/309.
Program the Panel at the Keypad
-
Press 6653 (PROG), then CMD at the keypad to enter the PROGRAMMER menu.
-
Press CMD until you see ZONE INFORMATION, then press any select key or area.
-
Configure the following options as needed:
|
Keypad Display |
Description |
|---|---|
Zone Number
ZONE NO: - |
Enter the key fob zone number (400-499). |
Key Fob User Number
KEY FOB USER #: - |
Enter the user number from 1 to 309999 used to identify the key fob user. The default is blank. |
Key Fob Serial Number
TRANSMITTER SERIAL#: - |
Enter the 8-digit serial number found on the key fob. |
Key Fob Transmitter Supervision Time
TRANSMITTER
SELECT MINUTES:
|
Enter the Supervision Time (0, 60, or 240) required for the key fob zone. The default is 0, which indicates an unsupervised transmitter. The key fob automatically checks in at least once during this time or a missing condition is indicated for that zone. When the panel is reset or a receiver is installed or powered down and powered up, the supervision timer restarts for all wireless zones. |
Number of Key Fob Buttons
NO OF KEY FOB BUTTONS:
|
Enter the number of buttons (1, 2, or 4) on the key fob. If the key fob is a 1-button model, programming continues at Button Action. Default button assignment for 1-button key fobs is a Panic alarm with no output assigned. |
Key Fob Button Selection
BUTTON:
|
Select one of the following buttons to program the action when pressed: TOP β Arming with no areas assigned BTM β Disarming with no areas assigned 4-Button Only LFT (Left) β Panic alarm with no output assigned RGT (Right) β Arming with Area 1 assigned |
Button Action
BUTTON ACTION
ARM DIS TGL STA PN PN2 EM EM2 OUT RST UN |
Select one of the following button actions for an individual key fob button:
|
Button Press Time
BUTTON PRESS TIME:
SHORT LONG |
Select the amount of time the user should press the button before the key fob sends a message to the receiver. SHORT β Press the button for a 1/2 second to send the message to the receiver. LONG β Press the button for 2 seconds to send the message to the receiver. |
Arm/Disarm Areas
ARM/DIS AREAS: |
Enter the area number that is armed or disarmed according to the key fob button programming. To arm or disarm selected areas, the userβs Group assigned to the user number needs to have the same area numbers selected. Any area may be selected at Arm/Disarm Areas but only matching area numbers are armed or disarmed when the specific button is pressed. When more areas are selected at Arm/Disarm Areas than are authorized in the userβs Group, the user can be given access authority to additional areas through the without requiring additional panel programming. |
Output Number
OUTPUT NO: - |
Enter the Output to operate when the button is pressed. |
Output Action
OUTPUT ACTION: STD PLS MOM TGL OFF |
Select one of the following output actions for the selected output number:
Note: Pulse is not available for key fob button output programmed D1 to D16 or G1 to G20.
|
-
When you are finished, continue programming additional menus as needed, or press CMD until STOP displays, then press any select key or area to save the panel programming.
Program the Panel in Dealer Admin
Note: Key fobs are programmed in Programming > Key Fobs in Dealer Admin, regardless if they are programmed using zones 400-499 or 500-999. If you are using a keypad to program, key fobs are always programmed in Zone Information.
Before You Begin
-
Verify the panel is connected to network
-
Log in to Dealer Admin.
-
Go to Customers, then select the System Name.
-
Go to Programming > Key Fobs.
-
Configure the following options as needed:
|
Keypad Display |
Description |
Key Fob Number
|
Enter the key fob zone number (400-499 or 500-999). |
Number of Buttons
|
Select the number of buttons (1, 2, or 4) on the key fob. |
Name
|
Enter the name of the key fob zone. |
Username
|
Select the username you want to associate with the key fob. |
User Number
|
The user number is automatically generated once you select the username. |
Serial Number
|
Enter the 8-digit serial number found on the key fob. |
Supervision Time
|
Enter the Supervision Time (0, 60, or 240) required for the key fob zone. The default is 0, which indicates an unsupervised transmitter. The key fob automatically checks in at least once during this time or a missing condition is indicated for that zone. When the panel is reset or a receiver is installed or powered down and powered up, the supervision timer restarts for all wireless zones. |
Program Top, Bottom, Left, and Right Button Options
Note: Top and Bottom display for 2-button key fobs only. Top, Bottom, Left, and Right display for 4-button key fobs only. |
|
Action
|
Select one of the following button actions for an individual key fob button:
|
Press Time
|
Select the amount of time the user should press the button before the key fob sends a message to the receiver. Short β Press the button for a 1/2 second to send the message to the receiver. Longβ Press the button for 2 seconds to send the message to the receiver. |
Areas
|
Enter the area number that is armed or disarmed according to the key fob button programming. To arm or disarm selected areas, the userβs Group assigned to the user number needs to have the same area numbers selected. Any area may be selected at Arm/Disarm Areas but only matching area numbers are armed or disarmed when the specific button is pressed. When more areas are selected at Arm/Disarm Areas than are authorized in the userβs Group, the user can be given access authority to additional areas through the without requiring additional panel programming. |
Output
|
Enter the Output to operate when the button is pressed. |
Output Action
|
Select one of the following output actions for the selected output number:
Note: Pulse is not available for key fob button output programmed D1 to D16 or G1 to G20.
|
-
When you are finished, select one of the following options:
-
-
If you are finished with all programming β Select Send All Changes at the top of the screen. This sends all programming changes to the panel.
-
If you are finished programming Key Fobs only β Select the More icon
, then select Send Key Fobs. This only sends key fob programming changes to the panel.
-