XR650 Installation and Programming Guide

Key Fobs

Note: To program a key fob, set the Wireless House Code in System Options to 1-50.

This section allows you to program 1144 Series Key Fobs. Zones 400-499 can be programmed as key fobs. See the 1144 Series Key Fob Installation Guide for more information.

To operate arming and disarming properly, ensure the key fob is assigned to a user number with appropriate area assignments. However, the user number does not have to exist at the time the key fob is programmed. The key fob user number can be added later.

Note: 1144 Series Key Fobs can also be programmed as 1-button or 2-button wireless Panic or Holdup zones. The available zone range is 500-999. Programming key fobs as panic zones requires 100XH Series Wireless Receivers Version 209/309.

Program the Panel at the Keypad

  1. Press 6653 (PROG), then CMD at the keypad to enter the PROGRAMMER menu.

  2. Press CMD until you see ZONE INFORMATION, then press any select key or area.

  3. Configure the following options as needed:

Keypad Display

Description

Zone Number

ZONE NO: -

Enter the key fob zone number (400-499).

Key Fob User Number

KEY FOB USER #: -

Enter the user number from 1 to 309999 used to identify the key fob user. The default is blank.

Key Fob Serial Number

TRANSMITTER SERIAL#: -

Enter the 8-digit serial number found on the key fob.

Key Fob Transmitter Supervision Time

TRANSMITTER
SUPRVSN TIME: 0

SELECT MINUTES:
0 60 240

Enter the Supervision Time (0, 60, or 240) required for the key fob zone. The default is 0, which indicates an unsupervised transmitter.

The key fob automatically checks in at least once during this time or a missing condition is indicated for that zone.

When the panel is reset or a receiver is installed or powered down and powered up, the supervision timer restarts for all wireless zones.

Number of Key Fob Buttons

NO OF KEY FOB BUTTONS:
-

Enter the number of buttons (1, 2, or 4) on the key fob.

If the key fob is a 1-button model, programming continues at Button Action. Default button assignment for 1-button key fobs is a Panic alarm with no output assigned.

Key Fob Button Selection

BUTTON:
TOP BTM LEFT RGT

πŸ“ Displays if you are programming a 2- or 4-button key fob

Select one of the following buttons to program the action when pressed:

TOP β€” Arming with no areas assigned

BTM β€” Disarming with no areas assigned

4-Button Only

LFT (Left) β€” Panic alarm with no output assigned

RGT (Right) β€” Arming with Area 1 assigned

Button Action

BUTTON ACTION
TOP/BTM/LFT/RGT:

ARM DIS TGL STA

PN PN2 EM EM2

OUT RST UN

Select one of the following button actions for an individual key fob button:

  • ARM β€”Arm selected areas and force arm bad zones.

  • DIS (Disarm) β€” Disarm selected areas.

  • TGL (Toggle) β€” Toggle arm/disarm for selected areas and force arm bad zones when arming

  • STA (Status) β€” Allow the key fob LED to indicate the arm/disarm status of the system

  • PN (Panic) β€” Trigger a Panic zone type alarm with no restoral.

  • PN2 (Panic 2) β€”Trigger a Panic zone type alarm with no restoral when pressed simultaneously with any other Panic 2 button. No action occurs when pressed alone.

  • EM (Emergency) β€” Trigger an Emergency zone type alarm with no restoral.

  • EM2 (Emergency 2) β€” Trigger an Emergency zone type alarm with no restoral when pressed simultaneously with any other Emergency 2 button. No action occurs when pressed alone.

  • OUT (Output) β€” Allows an output to turn on Steady, Pulse, Momentary, Toggle, or Off.

  • RST (Sensor Reset) β€” Allow panel to perform a standard Sensor Reset.

  • UN (Unused): Perform no action.

Button Press Time

BUTTON PRESS TIME:
-

SHORT LONG

Select the amount of time the user should press the button before the key fob sends a message to the receiver.

SHORT β€” Press the button for a 1/2 second to send the message to the receiver.

LONG β€” Press the button for 2 seconds to send the message to the receiver.

Arm/Disarm Areas

ARM/DIS AREAS:

Enter the area number that is armed or disarmed according to the key fob button programming.

To arm or disarm selected areas, the user’s Group assigned to the user number needs to have the same area numbers selected. Any area may be selected at Arm/Disarm Areas but only matching area numbers are armed or disarmed when the specific button is pressed.

When more areas are selected at Arm/Disarm Areas than are authorized in the user’s Group, the user can be given access authority to additional areas through the without requiring additional panel programming.

Output Number

OUTPUT NO: -

πŸ“ Displays if Action is Panic, Panic 2 Btn, Emergency, Emergency 2 Btn, or Output

Enter the Output to operate when the button is pressed.

Output Action

OUTPUT ACTION:

STD PLS MOM TGL

OFF

Select one of the following output actions for the selected output number:

  • STD (Steady) β€” The output turns on and remains on.

  • PLS (Pulse) β€” The output alternates 1 second on and 1 second off.

Note: Pulse is not available for key fob button output programmed D1 to D16 or G1 to G20.

  • MOM (Momentary) β€” The output turns on once for 1 second.

  • TGL (Toggle) β€” The output alternates between the on state and off state. Each button press toggles the output state.

  • OFF β€” The output is turned off. The output may turn off according to other programming, such as another button press, a zone action, or a schedule.

  1. When you are finished, continue programming additional menus as needed, or press CMD until STOP displays, then press any select key or area to save the panel programming.

Program the Panel in Dealer Admin

Note: Key fobs are programmed in Programming > Key Fobs in Dealer Admin, regardless if they are programmed using zones 400-499 or 500-999. If you are using a keypad to program, key fobs are always programmed in Zone Information.

Before You Begin

  • Verify the panel is connected to network

  • Log in to Dealer Admin.

  1. Go to Customers, then select the System Name.

  2. Go to Programming > Key Fobs.

  3. Configure the following options as needed:

Keypad Display

Description

Key Fob Number

Enter the key fob zone number (400-499 or 500-999).

Number of Buttons

Select the number of buttons (1, 2, or 4) on the key fob.

Name

πŸ“ Displays if you are programming a key fob using zones 500-999

Enter the name of the key fob zone.

Username

πŸ“ Displays if you are programming a key fob using zones 400-499

Select the username you want to associate with the key fob.

User Number

The user number is automatically generated once you select the username.

Serial Number

Enter the 8-digit serial number found on the key fob.

Supervision Time

πŸ“ Displays if you are programming a key fob using zones 400-499

Enter the Supervision Time (0, 60, or 240) required for the key fob zone. The default is 0, which indicates an unsupervised transmitter.

The key fob automatically checks in at least once during this time or a missing condition is indicated for that zone.

When the panel is reset or a receiver is installed or powered down and powered up, the supervision timer restarts for all wireless zones.

Program Top, Bottom, Left, and Right Button Options

Note: Top and Bottom display for 2-button key fobs only. Top, Bottom, Left, and Right display for 4-button key fobs only.

Action

Select one of the following button actions for an individual key fob button:

  • Unused β€” Perform no action.

  • Arming β€” Arm selected areas and force arm bad zones.

  • Disarming β€” Disarm selected areas.

  • Toggle Arm/Disarm β€” Toggle arm/disarm for selected areas and force arm bad zones when arming

  • Status β€” Allow the key fob LED to indicate the arm/disarm status of the system

  • Panic β€” Trigger a Panic zone type alarm with no restoral.

  • Panic 2 Btn β€”Trigger a Panic zone type alarm with no restoral when pressed simultaneously with any other Panic 2 button. No action occurs when pressed alone.

  • Emergency β€” Trigger an Emergency zone type alarm with no restoral.

  • Emergency 2 Btn β€” Trigger an Emergency zone type alarm with no restoral when pressed simultaneously with any other Emergency 2 button. No action occurs when pressed alone.

  • Outputβ€” Allows an output to turn on Steady, Pulse, Momentary, Toggle, or Off.

  • Sensor β€” Allow panel to perform a standard Sensor Reset.

Press Time

Select the amount of time the user should press the button before the key fob sends a message to the receiver.

Short β€” Press the button for a 1/2 second to send the message to the receiver.

Longβ€” Press the button for 2 seconds to send the message to the receiver.

Areas

Enter the area number that is armed or disarmed according to the key fob button programming.

To arm or disarm selected areas, the user’s Group assigned to the user number needs to have the same area numbers selected. Any area may be selected at Arm/Disarm Areas but only matching area numbers are armed or disarmed when the specific button is pressed.

When more areas are selected at Arm/Disarm Areas than are authorized in the user’s Group, the user can be given access authority to additional areas through the without requiring additional panel programming.

Output

πŸ“ Displays if Action is Panic, Panic 2 Btn, Emergency, Emergency 2 Btn, or Output

Enter the Output to operate when the button is pressed.

Output Action

Select one of the following output actions for the selected output number:

  • Off β€” The output is turned off. The output may turn off according to other programming, such as another button press, a zone action, or a schedule.

  • Pulse β€” The output alternates 1 second on and 1 second off.

Note: Pulse is not available for key fob button output programmed D1 to D16 or G1 to G20.

  • Steady β€” The output turns on and remains on.

  • Momentary β€” The output turns on once for 1 second.

  • Toggle β€” The output alternates between the on state and off state. Each button press toggles the output state.

  1. When you are finished, select one of the following options:

    • If you are finished with all programming β€” Select Send All Changes at the top of the screen. This sends all programming changes to the panel.

    • If you are finished programming Key Fobs only β€” Select the More icon menu.png , then select Send Key Fobs. This only sends key fob programming changes to the panel.

Last updated: